• Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
  • Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
  • Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
  • Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
  • Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
  • Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal

Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal

Structure: Standard
Pressure: 2.5MPa
Speed: Standard
Temperature: Standard
Performance: Standard
Standard: Standard
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
Thermosiphon tank
Type
Standard
Balance
Standard
Manual Refill Pump
Thermosiphon Vessel
Pressure Switch
Double Cartridge Seal
High Level Switch
Thermosiphon Tank
Low Level Switch
Cooling Tank
Temperature Gauge
Rinse Solution
Pressure Gauge
Quench System
Sight Glass
Flush System
Cooling Coil
Heat Exchanger
Plan 53A
Fluid Barrier Tank
Plan 52
Seal Tank
Seal Pot
Balance Vessel Pot
Thermosiphon Vessel
Heat Exchanger
Tank
Reservoir
Reservoir
Fluid Barrier Tank
Sealing System
Thermosiphon Vessel
Transport Package
Neutral Packing
Specification
4L-20L
Trademark
Trisun
Origin
China
HS Code
84799090
Production Capacity
50000

Product Description

thermosiphon system: Thermosiphon Tank is used to store and cool the buffer liquid for the double mechanical seals, operated as a closed circuit. It is able to compensate the leakage of the buffer liquid at the double mechanical seals to avoid drying running of the seals, thus improve the performance and duty life of the seals.

The buffer liquid flows to the Thermosiphon Tank from the double mechanical seals with the principle of Thermosiphon Effect (or by forced circulation), and returns to the seals being exchanged and cooled.

The TS series Thermosiphon Tank is built in SS304 or SS316L, with pressure gauge, sight glass, all necessary connection nozzles and brackets for easy installation. The tank can be built with or without cooling coil with the purpose to cool the buffer liquid by cooling water.

Besides thermosiphon vessels, if you need mechanical seals, sealing water meter, heat exchanger, hand pumps etc, pls. contact Ms. Lucy Liu. 

 

API Plan 21  The flushing plan from the outlet of the pump through the restrictor orifice and the heat exchanger into the mechanical seal chamber.

 

API Plan 23 The cyclic cooling&flushing plan of which the flushing fluid flows through the heat exchanger along the pumping ring of the mechanical seal chamber and then back to the sealing chamber. suitable for working conditions supplied with boiler water or hot water above 80ºC,as well as working conditions like hydrocarbons and chemical fluids.

 

API Plan 52 use external tank to provide buffer for an non-pressurized , double-end mechanical seal. This solution is usually used in occasions where the pumped liquid must be restricted from leaking to the atmosphere, and it is also used in places where the pumped liquid will solidify in the atmosphere or heat caused by inside mechanical seals need to be cooled .

 

API Plan 53A uses external air to isolate the liquid storage tank, and to provide clean isolation liquid for the sealing cavity of double-end mechanical seal.This solution is used for occasions where the pumped fluid cannot leak to the atmosphere.

 

API Plan 53B is a way to use bladder accumulator to provide pressure to the circulatory system. The circulation of the Isolation fluid is realized by installing a pumping ring.


Thermosiphon Tank Cooling Tank Flush System for Double Cartridge SealThermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal

Thermosiphon Tank Cooling Tank Flush System for Double Cartridge SealIt is seal support system, fluid barrier, seal pot, sealing tank, Pressure Reservoir  for double mechanical seals, for API 52, API53, API 53A.
It is made of stainless steel. 
Its volume has 3Gallon, 5 Gallon, 4L, 6L, 10L, 12L, 20L or based on your requirement. 




Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal


thermosiphon system: it is possible to supply buffer/barrier fluid to double and tandem mechanical seals for a broad range of applications. TS vessels are equipped as standard with all the necessary system connections and brackets, suitable for Plan 52, Plan 53A.

It helps to flush sealing faces and reduce temperature and pressure.

Besides thermosiphon vessels, pls. check our double cartridge seals.

Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal
Thermosiphon Tank Cooling Tank Flush System for Double Cartridge Seal




 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now